Technical Data | LWI V Nd:YAG 120 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 120 W |
energy adjustment mode | voltage or PWM mode |
voltage | 160-500V |
pulse width | 1-20 ms |
pulse frequency | 1-20 hz |
pulse fill | 10 - 100 % |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 200 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, water/air heat-exchanger, temperature controlled fan |
cooling option | external cooler optional, integrated bypass-controller |
electrical supply | 3 phases, 400V /50 hz |
power consumption | 4 kW |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V Nd:YAG 150 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 150 W |
energy adjustment mode | voltage or PWM mode |
voltage | 160-500V |
pulse width | 1-20 ms |
pulse frequency | 1-20 hz |
pulse fill | 10 - 100 % |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 200 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, water/air heat-exchanger, temperature controlled fan |
cooling option | external cooler optional, integrated bypass-controller |
electrical supply | 3 phases, 400V /50 hz |
power consumption | 4 kW |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V Nd:YAG 200 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 200 W |
energy adjustment mode | voltage or PWM mode |
voltage | 200-500V |
pulse width | 1-30 ms |
pulse frequency | 1-30 hz |
pulse fill | 10 - 100 % |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 200 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, water/air heat-exchanger, temperature controlled fan |
cooling option | external cooler optional, integrated bypass-controller |
electrical supply | 3 phases, 400V /50 hz |
power consumption | 4 kW |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V Nd:YAG 300 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 300 W |
energy adjustment mode | voltage or PWM mode |
voltage | 200-700V |
pulse width | 1-30 ms |
pulse frequency | 1-30 hz |
pulse fill | 10 - 100 % |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 200 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, water/air heat-exchanger, temperature controlled fan |
cooling option | external cooler optional, integrated bypass-controller |
electrical supply | 3 phases, 400V /50 hz |
power consumption | 4 kW |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V FSS 150 W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 15 joule |
max. peak power | 1,5 kW |
max. average power | 150 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | - |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | - |
electrical supply | 1 phase, 90-250V, 50/60 hz |
power consumption | 800 W |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V FSS 300 W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 30 joule |
max. peak power | 3 kW |
max. average power | 300 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | - |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | - |
electrical supply | 1 phase, 90-250V, 50/60 hz |
power consumption | 1,2 kW |
dimensions | 1487mm x 995mm x 790mm |